Scope
The short answer
On a blend report, read identity once per component, content once per component, and treat the purity figure as a single result for the whole sample. Then match the lot number and confirm the report with the issuing laboratory.
This guide describes how an analytical document is laid out. It is documentation education for laboratory and research-identification context, not guidance for human or veterinary use, and it makes no claims about effects.
Why a blend report is different
A certificate of analysis (COA) for a single compound answers three questions: is it the right molecule, how much is there, and how pure is the sample. A report for a mixed material has to answer the first two for each component, on one sample, under one lot number. That makes it easy to read the wrong line, so it helps to know the layout.
The worked example: lot COA9798
DAAVY lists a four-component research material, KLOW 80 mg, labeled as GHK-Cu 50 mg, BPC-157 10 mg, TB-500 10 mg and KPV 10 mg [1]. Its report, COA9798, was issued by Bioviridian on September 25, 2026, after the sample was received on September 21 [2]. The sample is described as blue lyophilized powder and the lot number is KLW-07072026 [2].
Identity: one check per component
Identity is established by mass spectrometry, which measures molecular weight. For a blend, the report should list a measured mass for each component. This report lists 342.4, 403.2, 1419.5 and 4964.2 g/mol, and its identity line names KPV, GHK-Cu, BPC-157 and TB-500 as confirmed by LC-MS/MS, marked "Conforms" [2]. The four masses are far apart, so no component could be mistaken for another. For why mass-spec output can show several peaks per compound, see the molecular weight guide.
Content: compare each number to its own label
Content is reported per component by HPLC quantitation: 10.33 mg KPV, 50.62 mg GHK-Cu, 10.48 mg BPC-157 and 10.17 mg TB-500 [2]. Added together that is 81.60 mg against an 80 mg labeled total. Each component sits a little above its own label: roughly 3% for KPV, 1% for GHK-Cu, 5% for BPC-157 and 2% for TB-500, by simple arithmetic on the listed figures. Small differences like these are common in analytical work, and why a vial can test above its label claim explains why. The habit to build is comparing every component to its own label line, not only the total.
Purity: one figure for the whole sample
The report lists "Overall Purity" of 99.80% by RP-HPLC at 214 nm [2]. In a mixture that is a single result for the sample, not a separate figure per component, and the report does not break it down. Its chromatogram shows the sample eluting in two groups, at retention times of about 1.9 to 2.1 minutes and about 9.1 to 9.3 minutes [2]. Purity also says nothing about how much peptide is in the vial; that is the content line, covered in purity vs peptide content. A related question is what a retention time does and does not prove.
Lot, date and verification
A report describes the sample tested. Match the lot number on the report to the lot on your material, and note the issue date. The report prints a Web Verification Code (here COA9798) and tells readers to confirm authenticity on the laboratory's own website, bioviridians.com/coa-search.html [2]. Doing that is worth the minute it takes, because it checks the document against the source rather than against a copy.
Limitations and risks of over-reading a COA
A COA covers one tested sample. It does not guarantee other lots, and it does not by itself establish sterility, endotoxin levels, long-term stability or suitability for any particular experiment. Published research on each named component exists independently, and DAAVY's overview states that no study of this specific four-component combination is cited or implied [3]. Methods differ between laboratories, so numbers from different reports are not strictly comparable without knowing the conditions. Nothing here is guidance for use.
References
- DAAVY Research, KLOW 80 mg product page (accessed November 14, 2026).
- Bioviridian, Certificate of Analysis COA9798, KLOW 80mg, lot KLW-07072026, issued September 25, 2026 (view in the COA viewer).
- DAAVY Research Academy, KLOW Blend: Research Overview (accessed November 14, 2026).
Figures such as the percentage differences are simple arithmetic on the report's listed values.